Vacuum Furnace Service (case 2) Function Optimization And Upgrading Of Vacuum Heat Treatment Furnace

Feb 08, 2022

Vacuum furnace service (case 2)

     Function optimization and upgrading of vacuum heat treatment furnace

 

Customer demands:

1.      When in use, the bearing beam breaks for many times, and the bearing capacity needs to be increased.

2.      Unreasonable furnace design leads to uneven cooling at the lower part, which needs to be improved.

3.      The ceramic parts are broken many times.

 

 1

Photo 1 unreasonable furnace design and uneven cooling

 

2

Photo 2 serious brittle crack of ceramic parts

 

 

Solution:

1.      The static analysis optimizes the structural design to improve the bearing capacity of the bearing beam.

2.      Optimize the design, change the substructure and size, and improve the cooling uniformity.

3.      Stress analysis optimizes ceramic parts and reduces ceramic fragmentation.

 

3

Figure 3 static analysis to optimize the mechanism design and improve the bearing capacity of the bearing beam

 

4

Figure 4 static analysis to optimize mechanism design and reduce ceramic fragmentation

 

5

Figure 5 optimize the design, change the substructure and size, and improve the cooling uniformity